How do I program CPLD 1 and CPLD 2 for MBD-X14DBG-DAP using SAA tool?
Print
Answer
You may use the following command: 

saa -i {BMC IP} -u {BMC USERNAME} -p {BMC PASSWORD} -c UpdateCPLD --file {CPLD FW PATH} --index {1 or 2} --reboot

  • Please note that index 1 corresponds to CPLD1 and index 2 corresponds to CPLD2
  • --reboot will power cycle the system as needed after updating the CPLD firmware. 