X13DEG-OAD

X13 Delta Next

Key Features


  1. Support HBM
  2. 5th/4th Gen Intel® Xeon® Scalable processors and Intel® Xeon® Max series processors, Dual Sockets LGA-4677 (Socket E) supported, CPU TDP supports Up to 350W TDP
  3. Intel C741® Chipset
  4. Up to 8TB 3DS ECC RDIMM, DDR5-5600MT/s in 32 DIMM slots
  5. 12 PCIe 5.0 MCIO x8
...
...

Optimized Servers


Specifications Resources Parts List
Specifications
Product SKUs
MBD-X13DEG-OAD
Physical Stats
Form Factor
  • Proprietary
Dimension
  • 15" x 17" (38.1cm x 43.18cm)
Processor
CPU
Core
  • Up to 64 cores
System Memory
Memory Capacity
  • 32 DIMM slots
  • Up to 8TB 3DS ECC RDIMM, DDR5-5600MHz
Memory Type
  • 5600/5200/4800/4400/4000 MT/s ECC DDR5 RDIMM (3DS) Up to 256GB of memory with speeds of up to 5600MT/s(1DPC) or 4400 MT/s (2DPC)
DIMM Sizes
  • 16GB, 32GB, 64GB, 96(XCC Only)GB, 128GB, 256GB
  • RDIMM: Up to 256GB
Memory Voltage
  • 1.1V
Error Detection
  • Corrects single-bit errors
  • Detects double-bit errors (using ECC memory)
On-Board Devices
Chipset
  • Intel® C741
SATA
  • Intel® C741 controller for 8 SATA3 ports
Network Controllers
  • N/A
Input / Output
TPM
  • 1 TPM Header
Expansion Slots
PCIe
  • 1 PCIe 5.0 x16 AIOM,
  • 12 PCIe 5.0 x8 PCIe5.0 MCIO connector
M.2
  • M.2 Interface: 2 PCIe 4.0 x4
  • Form Factor: 22110, 2280
  • Key: M-Key
System BIOS
BIOS Type
  • AMI 64MB AMI UEFI
BIOS Features
  • ACPI 6.4
  • SMBIOS 2.8/3.5
  • UEFI 2.8A
  • Plug and Play (PnP)
  • PCI FW 3.2
Management
Software
Security
Hardware
  • Trusted Platform Module (TPM) 2.0
PC Health Monitoring
Voltage
  • VBAT, System level control, Supports system management utility, Monitors CPU voltages, Chipset Voltage, Chassis intrusion header, 5 -fan status, +5V standby, +5V, +3.3V, +12V, Memory Voltages
LED
  • UID/Remote UID
  • CPU / System Overheat LED
Temperature
  • Monitoring for CPU and chassis environment
  • CPU thermal trip support
  • Thermal Monitor 2 (TM2) support
  • PECI
FAN
  • 2x 4-pin fan headers (up to 2 fans)
  • Fan speed control
  • 5 fans with tachometer status monitoring
  • Overheat LED indication
Other Features
  • UID, Node Manager Support, M.2 NGFF connector, Control of power-on for recovery from AC power loss, Chassis intrusion detection, ACPI power management
Operating Environment
Operating Temperature Range
  • 10°C - 35°C (50°F - 95°F)
Non-Operating Temperature Range
  • -40°C - 70°C (-40°F - 158°F)
Operating Relative Humidity Range
  • 8% - 90% (non-condensing)
Non Operating Relative Humidity Range
  • 5% - 95% (non-condensing)
Resources
Parts List
X13DEG-OAD (For SuperServer Only)
  1. Products